AMES d.o.o.
 
AMES
Enviromental measuring systems
 
SWS_250.jpg

SWS-250 Visibility and Present Weather Sensor

The Visibility Sensor measuresvisibility and present weather conditions and well as providing information on past weather.

  • General
  • Technical data
  • Documents
  • Video
  • Images

Features

Visibility measurement range 10m to 75km.

MOR and EXCO output.

Serial data output (RS232 & RS422/RS485).

Very low power requirements.

Data Output

The Visibility Sensor is provided with RS-232C and RS422/RS485 serial data outputs as standard for reliable and simple connection to a wide range of monitoring and control systems.

Construction

The Visibility Sensor is a single lightweight unit and can easily be installed by one person.

Maintenance and calibration

The Visibility Sensor is fully calibrated at the time of manufacture.

More information on: http://www.biral.com/meteorological-sensors/visibility-and-present-weather

Visibility range

Defoult 10m to 99.99km
Resolution 1m or 10m (defoult)

Visibility error <=4.5% at 600m
<=5.0% at 1500m
<=5.1% at 2km
<=12.5% at 15km
<=20% at 30km
Measurement principle forward scatter meter with 39° to 51° angle, centered at 45° 
Precipitation detection treshold

rain: 0.015mm/hr 
snow: 0.0015mm/hr

Maximum rain rate 500mm/hr
Rain intensity accuracy <=5%
Output data rate         serial 10 to 300sec (selectable)
Serial outputs   RS232, RS422 and RS485 
Present weather 42 WMO table 4680 codes
36 METAR present and past weather
Sensor power

9-36 VDC

Hood heating power

24VAC or DC
basic sensor 3.5W
window hweaters 2.5W
hood heaters 36W 

Operating temperature -40° to +60°
Operating humidity 0 - 100%RH
Protection rating IP66/IP67
Material  Aluminium, Powder paint finis with optional hard anodize base layer 
Weight 4.5kg include mounting kit 
Lenght 811mm
Warranty 3 years
Lifetime >10 years
User confidence check 6 month recommended
Window cleaning automatic compensation and warnings
Field calibration    with optional calibration kit
Included with sensor pole mounting kit (2 x U-bolt), user manual and calibration certificates
Additional features

hood heaters fitted as standard
window heaters fitted as standard
window contaminatin monitoring fitted as standard to all sensor head windows
Series data cable and power cable per meter, calibration kit, transit case, spares kit, 1 year extendd warranty, user defined precipitation definitions (per definition set), mains power adaptor

Certification and Compliance CE certified, EMC compliance with EN61326-1997, 1998, 2001, RoHS and WEEE compliant

 